成人午夜高潮视频,亚洲欧美色图小说,性爱视频在线播放,精品久久蜜桃

Small meteorological station
Small meteorological station

Product Center

Contact Us

Shandong Wanxiang Environmental Technology Co., Ltd

contacts :Manager LIU

Telephone :13276362033

QQ:1294284350

Company Address:The second floor of the first accelerator of the Optoelectronic Industry Park, No. 155 Incubation Second Lane, High tech Zone, Weifang City, Shandong Province

Ammonia nitrogen detector

Ammonia nitrogen detector

update time :2025-04-29

Model:WX-SS5

Product Price: Electronic Negotiation

Product brand: Wanxiang Environment

Ammonia nitrogen detector, also known as portable multi parameter water quality analyzer, is an instrument used to detect ammonia nitrogen and pH parameters in water quality. The instrument is easy to operate, stable in performance, accurate in measurement, and has a wide detection range, making it convenient for users to conduct water quality testing in the field or laboratory at any time.
product details
  1. Ammonia nitrogen detector Product Introduction

Ammonia nitrogen detector, also known as portable multi parameter water quality analyzer, is an instrument used to detect ammonia nitrogen and pH parameters in water quality. The instrument is easy to operate, stable in performance, accurate in measurement, and has a wide detection range, making it convenient for users to conduct water quality testing in the field or laboratory at any time.

The SS5 model portable multi-parameter water quality measuring instrument is an electrode method water quality analysis instrument that uses full digital electrode detection to detect ammonia nitrogen and PH parameters of water quality. The instrument is equipped with a self-developed FTIOT operating system, which has simple operation, stable performance, accurate measurement, wide detection range, and has a built-in high-capacity rechargeable lithium battery, which is convenient for users to conduct water quality inspection at any time in the field and in the laboratory.

2.Ammonia nitrogen detector  Host parameters

Charging input voltage4.5V-5.5V
Charging current<2A
Screen size3.5 inches
Screen resolution480*800 ☆
Screen interfaceMIPI DSI ☆
USB port2 (Support external expansion of mouse, keyboard, 4G, etc.) ☆
Type-C1 (Support external expansion of mouse, keyboard, 4G, etc.) ☆
RS4852 (Support Modbus, json, asc input, etc.)
External sensor power supply voltage12V
External sensor power supply current1A
operating systemftiot (based on Linux-5.4) ☆
CPU2*Cotex-A7, 650Mhz ☆
RAM512M DDR3 ☆
Flash8G-64G
OpenGLES 2.0 ☆
Wifisupport
4GSelection
buttonsupport
Capacitive touch screensupport
Software ArchitectureB/S ☆
Web accessSupport ☆
MTP modeSupport ☆
Multi-terminal loginSupport ☆
IPV6Support ☆
Sensor communication methodRS485, TCP, UDP, Http ☆
Data forwarding methodRS485, TCP, UDP, Http ☆
Remote SSHSupport ☆
Remote debuggingSupport ☆

3. Sensor parameters and configuration

Serial numbernameMeasurement rangeprincipleMeasurement accuracyResolutionConfigurationRemark
1temperature0~50℃High-precision digital sensor±0.3℃0.01℃

2pH0~14 (ph)Electrochemistry (salt bridge)± 0.1PH0.01

3ORP-1500mv~1500mvElectrochemistry (salt bridge)± 6mv1mV

4Conductivity0~5000uS/cm, 0~10000uS/cmContact electrode method± 1.5%1uS/cm

5TDS0-10000ppm 0-200pptContact electrode method±1.5%; ±0.1°C1ppm 0.01ppt

6salinity0-10000ppm 0-200pptContact electrode method±1.5%; ±0.1°C1ppm 0.01ppt

7Sludge concentration0~20.000g/LScattering light method±5% (depending on sludge homogeneity)0.001g/L

8Turbidity0~40NTU (low turbidity)Scattering light method± 1%0.1NTU
Optional
0~1000NTU (medium turbidity)Scattering light method± 1%
0~3000NTU (high turbidity)Scattering light method± 1%
9Dissolved oxygen0~20mg/LFluorescence life method± 2%0.01mg/L

10Ammonia nitrogen0~100mg/l, 0~1000.00mg/lIon Selection Electrode Method±1mg0.01mg?Range optional
11Suspension0~2000mg/LScattering light method±5% (depending on sludge homogeneity)0.1mg/L

12Residual chlorine0~5.00 mg/LIon Selection Electrode Method±5% of reading0.01mg/L
The best accuracy is when the flow rate is 0.42m/s-0.85m/s
13Chloride ions0-3500.0mg/LIon Selection Electrode Method±5%0.1mg/L

14Total hardness0~1000.0mg/LIon Selection Electrode Method±10% of reading0.1mg/L

15cod0~500mg/ LUV254 absorption method±5%0.1mg/L
COD and chlorophyll have automatic cleaners, which can prevent biological adhesion and avoid light window contamination, so as to ensure that long-term monitoring is still stable; automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W
16Chlorophyll0~400ug/LFluorescence methodR2>0.9990.01ug/L



Product address:http://www.0757gl.com/en/shuizhi/1408.html
Hello, my friend!
What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
WeChat
Phone
Country
*Message
主站蜘蛛池模板: 奈曼旗| 永善县| 四会市| 张家港市| 维西| 那曲县| 额济纳旗| 汉沽区| 朝阳市| 张家口市| 天水市| 江油市| 阳谷县| 景洪市| 天长市| 平远县| 萝北县| 德阳市| 扎囊县| 涿鹿县| 江陵县| 福清市| 汪清县| 庐江县| 灵寿县| 阳泉市| 贵阳市| 湖北省| 深州市| 兴义市| 隆子县| 福建省| 广宗县| 黔西县| 台东县| 衢州市| 赤壁市| 新安县| 郎溪县| 巴东县| 陕西省|